Explosion-proof certification standards for vacuum pressure switches

Explosive-Proof Certification Standards for Vacuum Pressure Switches

International Standards for Explosive Atmospheres

IECEx and ATEX Directives for Global Markets

Vacuum pressure switches used in explosive environments must comply with IECEx (International Electrotechnical Commission System for Certification) and ATEX (EU Directive 2014/34/EU) standards. These frameworks ensure devices are safe for use in zones classified as Zone 0, Zone 1, or Zone 2 for gases and Zone 20, Zone 21, or Zone 22 for dust. For example, switches in Zone 0 require Ex ia (intrinsic safety) or Ex d (flameproof) protection, while Zone 2 devices may use Ex m (encapsulation). ATEX certification mandates rigorous testing for ignition sourcestemperature limits, and mechanical durability under simulated explosive conditions.

IEC 60079 Series for Electrical Equipment

The IEC 60079 series defines safety requirements for electrical devices in hazardous areas. Key standards include:

  • IEC 60079-0: General requirements for equipment construction and testing.

  • IEC 60079-1: Flameproof enclosures (Ex d) to contain internal explosions.

  • IEC 60079-11: Intrinsic safety (Ex ia/ib) to limit electrical energy below ignition thresholds.

  • IEC 60079-31: Protection against dust ingress (Ex tD) for equipment in combustible dust environments.


    These standards apply to vacuum pressure switches by specifying material selectionsealing techniques, and electrical insulation to prevent spark generation.

Regional Compliance Requirements

China’s GB 3836 Standards

China’s GB 3836 series aligns with IEC 60079 but includes additional national requirements. For example:

  • GB 3836.1: General provisions for equipment design and testing.

  • GB 3836.2: Flameproof enclosures (Ex d) with stricter pressure-testing protocols.

  • GB 3836.4: Intrinsic safety (Ex ia) with lower allowable voltage/current limits.


    Manufacturers must obtain CCCF certification (China Compulsory Certificate) and submit products to CNAS-accredited labs for validation. Switches used in coal mines require MA certification (Mine Safety Mark) under GB/T 12173.

North American NEC and UL Standards

In the United States and Canada, vacuum pressure switches must meet NEC Article 500-506 (hazardous locations) and UL 60079 (explosive atmosphere safety). Key requirements include:

  • Class I, Division 1/2: For gas environments, with Division 1 requiring explosion-proof enclosures.

  • Class II, Division 1/2: For dust environments, with Division 1 mandating dust-tight seals.

  • UL 1203: Specific to explosion-proof electrical equipment, covering pressure testingtemperature ratings, and marking requirements.


    Certification involves factory inspections and annual audits to ensure ongoing compliance.

Technical Specifications for Explosion Protection

Enclosure Design and Materials

Vacuum pressure switches must use non-sparking materials like stainless steel or aluminum alloys with anti-corrosive coatings. For flameproof enclosures (Ex d), standards specify:

  • Gap width: ≤0.15 mm for metal joints to prevent flame propagation.

  • Surface roughness: ≤6.3 μm to minimize particle adhesion in dust environments.

  • Thread engagement: Minimum 5 threads for screwed connections to maintain pressure integrity.

Electrical Safety and Ignition Prevention

Intrinsic safety (Ex ia) switches limit electrical energy to <0.2 mJ (gas) or <10 mJ (dust) to avoid ignition. Key measures include:

  • Voltage restriction: ≤30 V DC for gas environments under IEC 60079-11.

  • Current limiting: Use of Zener diodes or resistors to suppress surges.

  • Galvanic isolation: Optical or inductive coupling to separate control circuits from hazardous areas.

Temperature and Environmental Resistance

Switches must operate safely within temperature class T1–T6 (T1: ≤450°C, T6: ≤85°C). For example:

  • High-temperature zones: Use ceramic components to withstand >200°C.

  • Low-temperature zonesSilicone-based lubricants prevent freezing at -50°C.

  • Corrosive environmentsIP66/IP67 ratings protect against dust and water ingress, with salt-fog testing for coastal applications.