The preparatory work before the installation of vacuum pressure switches is a key link to ensure their normal operation and long-term stability. The following are the key preparations that need to be completed before installation:
Consult the technical manual
Carefully read the technical specification or user manual of the vacuum pressure switch to confirm whether its measurement range, accuracy, pressure unit (such as kPa, mbar, inHg, etc.), and electrical parameters (voltage, current, contact capacity) match the system requirements.
Example: If the vacuum degree requirement of the system is from -100 kpa to 0kPa, a switch with a range covering this range should be selected.
Check the interface specification
Confirm whether the interface type (such as threaded interface, flange interface) and size of the switch are compatible with the system piping or equipment.
Example: If the system adopts 1/4-inch NPT threads, a switch of the same specification needs to be selected.
Temperature and humidity
Confirm whether the temperature and humidity of the installation environment are within the allowable range of the switch (usually -20℃ to +80℃, humidity ≤85%RH). Avoid sensor drift or circuit failure caused by high temperature, low temperature or high humidity environments.
Vibration and Shock
If there is strong vibration or shock at the installation location (such as close to the motor or pump), a switch with an anti-vibration design should be selected, or shock absorption measures should be taken (such as installing shock-absorbing pads).
Corrosive medium
If the system medium is corrosive (such as acid or alkali), switches made of corrosion-resistant materials (such as stainless steel casings) should be selected, or protective measures should be added (such as installing isolation diaphragms).
Tool list
Prepare tools such as wrenches, screwdrivers, sealing tape, and raw material tape to ensure that the installation process will not be delayed due to the lack of tools.
Sealing material
Prepare appropriate sealing materials (such as PTFE raw tape, metal gaskets) according to the interface type to ensure there is no leakage at the connection.
For example, threaded interfaces need to be wound with raw tape, and flange interfaces need to use sealing gaskets.
Electrical connection materials
Prepare materials such as cables, terminal blocks, and insulating sleeves to ensure the safety and reliability of electrical connections.
System pressure relief and cleaning
Before installation, ensure that the system has been completely depressions and clean the impurities, oil stains, etc. inside the pipes or equipment to avoid contaminating the switch or affecting the measurement accuracy.
Check system compatibility
Confirm whether the working pressure, temperature, medium type, etc. of the system match the applicable range of the switch.
Example: If the system medium is corrosive gas, a corrosion-resistant type of switch should be selected.
Determine the installation location
Select a location that is convenient for operation and maintenance and can accurately reflect the system pressure. Avoid installing the switch in areas with high temperatures, vibrations or strong electromagnetic interference.
Plan the electrical wiring
Based on the electrical parameters of the switch and the system control requirements, plan the cable routing and wiring method to ensure that the wiring complies with safety regulations.
Prepare the debugging tools
Prepare tools such as a pressure calibrator and a multimeter for calibration and testing after installation.
Wear protective equipment
During the installation process, safety gloves, goggles and other equipment must be worn to prevent personal injury caused by improper operation.
Power-off operation
If electrical connections are involved, they should be carried out when the power is off to avoid the risk of electric shock.
Emergency response plan
Formulate emergency response plans for possible abnormal situations (such as leakage and short circuit) during the installation process to ensure safety.
Operator training
Ensure that the installers are familiar with the technical parameters, installation steps and precautions of the switch to avoid equipment damage caused by improper operation.
Communicate with the system integrator
If the switch needs to be integrated with control systems such as PLC and DCS, it is necessary to communicate with the system integrator in advance about the interface protocol, signal type and other details to ensure compatibility.
Summary
The preparatory work before the installation of vacuum pressure switches needs to be comprehensively prepared from multiple aspects such as equipment specifications, environmental conditions, tool materials, system status, installation plans, safety protection and personnel training. Through meticulous preparatory work, it can be ensured that the switch can operate stably after installation, reduce the risk of failure and extend the service life of the equipment.